Sensor power supply: | 5 – 12 V DC |
Consumption (idle at the lowest scanning speed) | 0,3 mA |
Output max. | 800 mA |
Sensing distance: | 0,15 – 1,5 m |
Wavelength equipment | 950 nm |
Optimal operating pressure | 0,1 – 0,5 MPa |
Maximum pressure | 0,8 MPa |
Time adjustment of valve opening | 1 – 30 s |
Fittings | G½ " |
Water flow at a pressure of 0.3 Mpa | 1,3 l |
Product details
- For automatic flushing of urinals
- For mounting frame A107S
- For installing into the urinal mounting elements
- For installation in plasterboard structures as well as walling-in
Application
- Battery power supply 6 V
- The removable cover plate – a combination of stainless steel/chrome–plated plastic
- Setting via mini USB using free software available on the Alca website
- Adjustable parameters: start and end time of registration, duration of flushing, automatic flush, allowing flooding, flooding time, variable settings hygienic rinse
- Pulse valve control
- Savings of water and electricity
- Material: stainless steel, chrome plated plastic
Specifications
-
Norms
EN 55014, EN 55022, EN 61000
Quantity (package) | 16 pcs |
Quantity (pallet) | 256 pcs |
Dimensions (piece) | 175×137×160 mm |
Dimensions (package) | 595×435×395 mm |
Weight (piece) | 1,7201 kg |
Weight (package) | 27,5216 kg |
Weight (pallet) | 460,3456 kg |
- Sensor box made of stainless steel
- Screw set with a solenoid valve
- Plastic chromed cover frame
- Tile template
- Suction pad for removing the cover plate
- Waterproof power connector
- Infrared sensor adjustable via a USB port
- Fixing material for attaching the covering frame: screw 3.5×32 – 4 pcs
- Fixation set for attaching the box on the frame: screw 3.5×16 – 4 pcs
- Screw fitting G1/2“
- Battery box for 4×AA batteries 1.5 V
Scope of supply
K1941-ND | Frame cover |
M0599-ND | Suction pad 30 mm |
M0676-ND | Screw 3,5×32 |
M0693-ND | Plate for urinal sensor, chrome-plated |
M1579-ND | Valve R mini–battery operated |
MN0035-ND | Battery box |
Downloads
File Name | Size | Action | |
ASP4-B - CAD drawing.dwg | 137.06 kB | Download | |
ASP4-B - CAD drawing.dxf | 376.9 kB | Download | |
ASP4-B - Installation instructions - SW: v. C.pdf | 3.83 MB | Download | |
ASP4-B - .xml | 3.83 MB | Download | |
ASP4-B - Installation instructions - SW: v. D.pdf | 5.43 MB | Download | |
ASP4-B - .xml | 5.43 MB | Download | |
ASP4-B - Declaration of conformity.pdf | 163.76 kB | Download | |
ASP4-B - Sensors - drivers.exe | 1.87 MB | Download | |
ASP4-B - Sensor settings - SW: C.pdf | 698.86 kB | Download | |
ASP4-B - Sensor settings - SW: D.pdf | 783.3 kB | Download | |
ASP4-B - IRC Setup v. C - software for settings sensor.exe | 4.71 MB | Download | |
ASP4-B - IRC Setup v. D - software for settings sensor.zip | 85.54 kB | Download |