Flush plate Antivandal with sensor for pre-wall installation systems, metal (AC power supply)
M279S
Product details
Operating force | < 20 N |
Output voltage | 12 V DC |
Power consumption | 8,5 W |
- For pre-wall installation systems and concealed WC cisterns
- For use in public buildings – Antivandal
- For touchless flushing with a sensor
- Can not be used for pre-wall installation systems Slim
- Can not be used for pre-wall installation systems AM118 and AM119, with top actuation
Application
- Massive construction from stainless steel
- Highly resistant to mechanical damage
- Locking screws are hidden inside of the flush plate
- Powered by the main electric supply, the power source must be purchased (12 V DC min 1 A) – recommended AEZ310
- Setting via mini USB using free software available on the Alca website
- Adjustable parameters: start and end time of registration, duration of flushing, automatic flush, allowing flooding, flooding time, variable settings hygienic rinse
- Magnetic switch for service setting and cleaning
- Option to use the button for a large flush
- Material: stainless steel
Specifications
-
Norms
EN 55014, EN 55022, EN 61000
Quantity (package) | 10 pcs |
Quantity (pallet) | 160 pcs |
Dimensions (piece) | 315×210×120 mm |
Dimensions (package) | 595×395×435 mm |
Weight (piece) | 1,9238 kg |
Weight (package) | 19,238 kg |
Weight (pallet) | 327,808 kg |
- Flush plate
- Infrared sensor
- Screw set with a solenoid valve
- Flush valve for sensor flushing
- Connector for attaching to the source
- Fixing frame of the flush plate
- Threaded frame clamp 2 pcs
- Fixing hardware for attaching the cover frame: screws M4×10 – 2 pcs
Scope of supply
M0014-ND | Mechanism screw, 2 pcs |
M0019-ND | Pull bar for A06 |
M0037-ND | Flush plate frame |
M0044-ND | Stopper |
M0532-ND | Screw M 4×10 |
Downloads
File Name | Size | Action | |
M279S - CAD drawing.dwg | 76.18 kB | Download | |
M279S - CAD drawing.dxf | 191.41 kB | Download | |
M279S - Installation instructions.pdf | 4.78 MB | Download | |
M279S - Template for correct flush plate setup.pdf | 240.87 kB | Download | |
M279S - Declaration of conformity.pdf | 65.28 kB | Download | |
M279S - Sensors - drivers.exe | 1.87 MB | Download | |
M279S - Sensor settings - SW: C.pdf | 698.86 kB | Download | |
M279S - Sensor settings - SW: D.pdf | 783.3 kB | Download | |
M279S - IRC Setup v. C - software for settings sensor.exe | 4.71 MB | Download | |
M279S - IRC Setup v. D - software for settings sensor.zip | 85.54 kB | Download |